Код ошибки |
Описание |
C010 |
Backup memory problem – The specified data was not written into
NVRAM |
C030 |
Serial communication problem (main PCB problem) – Communication
procedure fails to complete within 200 ms in any block. Nine
consecutive reception errors occur in one block |
C031 |
Serial communication problem (operation unit PCB problem) –
Communication procedure fails to complete within 200 ms in any
block. Nine consecutive reception errors occur in one block |
C032 |
Serial communication problem (servo motor PCB problem) – serial
communication between the main PCB and the servo motor PCB fails
five times consecutively |
C033 |
Serial communication problem (RDH main PCB problem) – Serial
communication between the copier main PCB and the RDH main PCB fails
five times consecutively |
C110 |
Halogen lamp problem – While the scanner motor rotates in
forward direction because of the lamp on signal, the HLISENS input
signal fails to go low. The HLISENS input signal fails to go low
during exposure correction |
C210 |
Paper conveying motor problem – No enКод ошибкиr signal is
received 250 ms after the paper conveying motor on signal has been
emitted |
C220 |
Side registration motor problem – The side registration home
position switch fails to turn on within 5 s after the main switch
has been turned on |
C230 |
Fewer than five pulses are generated by the drum motor enКод
ошибкиr in 1 s after the drum motor on signal has been emitted |
C240 |
Paper deck motor problem – The paper deck level switch or the
home position switch fails to turn on within 20 s after the paper
deck motor on signal has been emitted |
C250 |
Upper drawer motor problem – The upper drawer level switch or
the position switch fails to turn on within 8 s |
C251 |
Middle drawer motor problem – The middle drawer level switch or
the position switch fails to turn on within 8 s after the middle
drawer motor on signal has been emitted |
C252 |
Lower drawer motor problem – The lower drawer level switch or
the position switch fails to turn on within 8 s after the middle
drawer motor on signal has been emitted |
C310 |
Scanner motor problem (main PCB problem) – The home position
switch fails to turn on within 4 s after the scanner motor reverse
signal has been emitted |
C311 |
Scanner motor problem (servo motor PCB problem) – No signal is
generated by the enКод ошибкиr 20ms after the scanner motor reverse
signal has been emitted |
C312 |
Scanner motor problem3523 or more SM forward pulses are received
after the scanner motor has started to rotate forward. The scanner
motor speed exceeds the specified level |
C313 |
The home position switch fails to turn on within 4 s after the
SM HP signal has gone low |
C314 |
Servo motor CPU problem – With the scanner motor forward signal
on, the average motor speed exceeds 900 mm/s in any 60 ms (excluding
the first 20 ms after the signal is emitted;or with the scanner
motor reverse signal on, the average motor speed exceeds 1600 mm/s
in any 60 ms excluding the first 60 ms after the signal is
emitted |
C410 |
Lens motor problem – The lens home position switch fails to turn
on within 12 s after the lens motor home signal has been
emitted |
C510 |
Main high voltage problem – The short detection signal is
generated by the main charger high-voltage PCB for 5 s |
C520 |
Transfer high voltage problem – The transfer high voltage short
detection signal is generated by the transfer charger high-voltage
PCB for 5 s |
C521 |
Separation high-voltage problem – The separation high voltage
short detection signal is generated by the transfer charger
high-voltage PCB for 5 s |
C530 |
Pre-transfer high-voltage problem – The pre-transfer short
detection signal is generated by the pretransfer charger
high-voltage PCB for 5 s |
C540 |
Bias problem-The short detection signal is generated by the bias
PCB for 5 s |
C550 |
Potential sensor problem – During initial potential sensor
calibration, the difference between the sensor outputs when 500 V
and 300 V are applied to the drum is zero or negative |
C560 |
Potential adjustment problem: max level – During initial
potential settling, the drum potential cannot be set to the
specified level by increasing the primary main charger control
signal to its maximum |
C561 |
Potential adjustment problem: min. level – During initial
potential setting, the drum potential cannot be set to the specified
level by reducing the primary admin charger control signal to its
minimum |
C570 |
Exposure adjustment problem: max level – |
C571 |
Exposure adjustment problem: min level – During initial light
intensity correction, the potential sensor output cannot be set to
the specified level even with the halogen lamp control signal at
min |
C610 |
Fixing unit heater M wire broken – No heater check signal is
generated by the noise filter PCB 800 ms after the fixing unit
heater S off signal and the fixing unit heater M on signal have been
emitted |
C611 |
Fixing unit heater S wire broken – No heater check signal is
generated by the noise filter PCB 800 ms after the fixing unit
heater M off signal and the fixing unit heater S on signal have been
emitted |
C620 |
Fixing unit heats failing to turn off – The heater check signal
continues to be generated by the noise filter PCB 320 ms after the
fixing unit heater M and S off signals have been emitted |
C630 |
Fixing unit thermistor wire broken – The data generated by the
fixing unit thermistor remains at F1H or above for longer than two
minutes while fixing unit heaters M and S are on |
C640 |
Fixing unit thermistor wire shorted/abnormally high temperature
detected – Data from the fixing unit thermistor remains at 45H or
less for 160 ms or longer |
C641 |
Fixing unit thermistor abnormally low temperature detected – The
signal from the fixing unit thermistor registers 100C or lower
during standby or a copying cycle after secondary
stabilization |
C710 |
Toner sensor problem – Data from the toner sensor remains at 14H
or less, or F0H or above for 320 ms |
C720 |
Drum thermistor wire broken – The signal from the drum
thermistor remains high for 5 s |
C730 |
Drum thermistor shorted/abnormally high temperature detected –
The signal from the drum thermistor remains low for 5 s |
C731 |
Drum thermistor abnormally low temperature detected – The drum
heater remains on at 100% output for 17 minutes with the safety
switches on |
C740 |
Internal temperature thermistor broken – Data from the internal
temperature thermistor remains at 0CH or less for 320 ms |
C741 |
External temperature thermistor problem – Data from the external
temperature thermistor remains at F0H or above (too low a
temperature or broken wire) or at 33H or less (too high a
temperature or shorted wire) for 320 ms |
C750 |
Developing unit thermistor problem – Data from the developing
unit thermistor remains at F0H or above (too low a temperature or
broken wire) or at 33H or less (too high a temperature or shorted
wire) for 320 ms |
C760 |
Toner cartridge shutter problem – The shutter home position
switch fails to turn off within 10 s after the toner cartridge a
shutter mode on signal has been emitted. The shutter home position
switch fails to turn on within 40 s after it has turned off |
C761 |
Toner cartridge loading problem – The TCPSW1 or TCPSW2 signal
falls to be input within 40 s after the toner cartridge loading
motor on signal has been emitted |
C762 |
Toner hopper problem – No signal is input from the toner level
detection switch after automatic toner replenishing is
completed |
C810 |
Sorter feed motor problem – A feed motor problem – A feed motor
jam is detected (with the stapler-sorter attached). The feed motor
current exceeds 2 A for 50 ms (with the sorter attached) |
C811 |
Sorter feed motor circuit problem – No feed motor index signal
is detected for 30 ms (with the sorter attached) |
C820 |
Sorter bin drive motor problem – The sorter bin unit fails to
return to the home position during initialization (with the
stapler-sorter attached). The sorter shift motor current exceeds 1.2
A for 50 ms (with the sorter attached) |
C821 |
Sorter shift motor PCB problem (sorter) – No enКод ошибкиr
signal is detected from the sorter shift motor for 50 ms |
C830 |
Sorter table motor problem (stapler-sorter) – The sorters
stapler table fails to return to the home position during
initialization |
C831 |
Sorter bin side motor problem (stapler-sorter) – The bin fails
to return to the sliding home position during initialization. The
bin fails to move to the stapling/punching position. The bin fails
to return to the sliding home position |
C832 |
Sorter paper weight motor problem (stapler-sorter) – The sorter
paper weight fails to return to the home position during
initialization. The sorter paper weight fails to move to the
operating position when it should. The sorter paper weight fails to
return to the home position after releasing the paper |
C833 |
Sorter jog motor problem – The jog unit fails to return to the
home position during initialization. The job unit fails to move to
the standby position when paper is fed |
C840 |
Sorter bin upper limit detected (stapler-sorter) – The bin upper
limit sensor turns on while the sorter bin drive motor drives |
C841 |
Sorter bin unit lower limit detected (stapler-sorter) – The bin
unit lower limit sensor turns on while the sorter bin drive motor
drives |
C850 |
Sorter punch jam (stapler-sorter) – The punch fails to return to
the home position during initialization. The punch fails to return
to the home position during operation |
C851 |
Sorter stapler jam – The stapler fails to return to the home
position during initialization. The stapler fails to return to the
home position during operation. The stapler motor current exceeds 5
A for 30 ms (with the sorter) |
C852 |
Sorter stapler motor problem – A block signal fails to be input
from the home sensor within 100 ms after the stapler motor has
turned on. Home signal fails to be input within 250 ms after the
block signal has been emitted |
C860 |
Sorter shutter motor problem (auto stacker) – The sorter shutter
fails to close during initialization. The sorter shutter fails to
close during initialization. The sorter shutter fails to open during
operation. The sorter shutter fails to close during operation |
C861 |
Hand table motor problem (auto stacker) – The hand table fails
to return to the home position during initialization. The hand table
fails to move to the standby position during operation. The hand
unit fails to move to the standby position during operation. The
hand unit fails to return to the home position for paper
ejection |
C862 |
Hand unit drive motor problem (auto stacker) – The hand unit
fails to return to the home position during initialization. The hand
table fails to return to the home position during initialization.
The hand table fails to move to the standby position during
operation. The hand unit fails to move to the standby position
during operation. The hand unit fails to return to the home position
for paper ejection |
C863 |
Stapler-sorter-stacker communication problem – An error occurs
during serial communication between the stapler-sorter and the
auto-stacker |
C910 |
RDH original feed motor problem – No pulse is generated by the
pulse sensor for 800 ms or longer while the RDH original feed motor
is rotating |
C920 |
RDH original conveying motor problem – No pulses are generated
by the pulse sensor for 800 ms or longer while the RDH original
conveying motor is rotating. No pulses are generated by the pulse
sensor for 800 ms or longer while the RDH original conveying motor
is rotating |
C930 |
RDH original eject motor problem – No pulse is generated by the
pulse sensor for 800 ms or longer while the RDH original eject motor
is rotating |
C940 |
RDH original transfer motor problem – If the original transfer
plate home position switch fails to turn on during the 2.5 s when
the original transfer motor reverses for 2.5 s, which is repeated
twice. The home position switch does not turn on after this
process |
C950 |
RDH original jogging motor problem – If the RDH original jogging
guide home position switch fails to turn off 1 s or longer after the
original jogging motor has turned on |